FixVault

Component testing procedure

COMPONENT TESTING PROCEDURE CHART

Circuit to test Connect self-powered test light or ohmmeter to terminals Move switch to these positions A good switch will indicate
Tilt 1 and 3 Tilt Up Closed circuit
1 and 2 Down Open circuit
1 and 4 Open Open circuit
1 and 5 Close Open circuit
Down 1 and 3 Tilt Up Open circuit
1 and 2 Down Closed circuit
1 and 4 Open Open circuit
1 and 5 Close Open circuit
Open 1 and 3 Tilt Up Open circuit
1 and 2 Down Open circuit
1 and 4 Open Closed circuit
1 and 5 Close Open circuit
Close 1 and 3 tilt Up Open circuit
1 and 2 Down Open circuit
1 and 4 Open Open circuit
1 and 5 Close Closed circuit