Removal and Installation
- Disconnect the battery. For additional information, refer to BATTERY, BATTERY MOUNTING & BATTERY CABLES .
- Rotate the Front End Accessory Drive (FEAD) belt tensioner counterclockwise and position the FEAD belt aside.
- Disconnect the generator electrical connector.
- Position the generator B+ protective boot aside, remove the B+ nut and position the B+ terminal aside.
- To install, tighten to 17 Nm (150 lb-in).
- Remove the generator stud nut.
- To install, tighten to 48 Nm (35 lb-ft).
- Remove the generator bolt and the generator.
- To install, tighten to 48 Nm (35 lb-ft).
- To install, reverse the removal procedure.