FixVault

Solenoid Operation Chart

SOLENOID OPERATION CHART

Base Selector Lever Position PCM Commanded Gear SSA NL (1, 2, 3, 4) SSB NH (3, 5, R) SSC NL (2, 6) SSD NH (L, R/C 4, 5, 6) SSE (On/Off) NC TCC NL
P P Off On Off Off On Off
R R Off Off Off Off On Off
N N Off On Off Off On Off
D 1 On On Off Off (1) On (2) Off
  2 On On On On Off Off
  3 On Off Off On Off Off
  4 On On Off Off Off On/Off
  5 Off Off Off Off Off On/Off
  6 Off On On Off Off On/Off
(1) Turns on above 8 km/h (5 mph).
(2) Turns off above 8 km/h (5 mph).

NC = Normally closed
NH = Normally high
NL = Normally low