- Refer to the Diagnostic Routine
|
|
|
|
- Refer to the Diagnostic Routine
|
|
- The engine does not reach normal operating temperature
|
- Refer to the Diagnostic Routine
|
|
- The block heater does not operate correctly
|
|
- CHECK continuity in all 3 power cable circuits. If any circuit measures more than 5 ohms, INSTALL a new power cable.
|
|
|
- CHECK the resistance of the block heater. If the resistance does not measure between 12.5 and 17.0 ohms, INSTALL a new block heater.
|
- The electric cooling fan(s) is inoperative in one or more speeds or does not operate correctly
|
- Wiring
- Relays
- Fuses
- Fan Control (FC) module
- Cooling fan motor(s)
- Cooling fan resistor(s)
|
|
- The electric cooling fan(s) stays on all the time
|
|
|
- Noisy electric cooling fan operation
|
- Foreign material contamination
- Fan motor
|
- REMOVE the foreign material from the cooling fan and shroud. TEST the system for normal operation. If still noisy, INSTALL a new cooling fan assembly.
|
- Fan blade detached from fan motor
|
- INSTALL a new cooling fan assembly.
|