Solenoid Operation Chart

Base Selector Lever Position PCM Commanded Gear SSA NL (1, 2, 3, 4) SSB NH (3, 5, R) SSC NL (2, 6) SSD NH (L, R/C 4, 5, 6) SSE (On/Off) NC TCC NL
P P Off On Off Off On Off
R R Off Off Off Off On Off
N N Off On Off Off On Off
D 1 On On Off Off(1) On(2) Off
  2 On On On On Off Off
  3 On Off Off On Off Off
  4 On On Off Off Off On/Off
  5 Off Off Off Off Off On/Off
  6 Off On On Off Off On/Off
(1) Turns on above 8 km/h (5 mph).
(2) Turns off above 8 km/h (5 mph).