FixVault

Pinpoint Test Dz: Universal Heated Oxygen Sensor (Ho2S): Introduction

WARNING: TO PREVENT THE RISK OF HIGH-VOLTAGE SHOCK, ALWAYS FOLLOW PRECISELY ALL WARNINGS AND SERVICE INSTRUCTIONS, INCLUDING INSTRUCTIONS TO DEPOWER THE SYSTEM. THE HIGH-VOLTAGE SYSTEM UTILIZES APPROXIMATELY 300 VOLTS DC, PROVIDED THROUGH HIGH-VOLTAGE CABLES TO ITS COMPONENTS AND MODULES. THE HIGH-VOLTAGE CABLES AND WIRING ARE IDENTIFIED BY ORANGE HARNESS TAPE OR ORANGE WIRE COVERING. ALL HIGH-VOLTAGE COMPONENTS ARE MARKED WITH HIGH-VOLTAGE WARNING LABELS WITH A HIGH-VOLTAGE SYMBOL. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

This pinpoint test is intended to diagnose the following:

Pin Circuit
5 UO2SPCT11 (Universal Oxygen Sensor Pumping Current Trim Bank 1, Sensor 1)
1 UO2SPC11 (Universal Oxygen Sensor Pumping Current Bank 1, Sensor 1)
3 UO2SHTR11 (Universal Oxygen Sensor Heater Bank 1, Sensor 1)
2 UO2SGREF11 (Universal Oxygen Sensor Ground Reference Bank 1, Sensor 1)
6 UO2S11 (Universal Oxygen Sensor Bank 1, Sensor 1)
4 VPWR (Vehicle Power)
Fig 2: Identifying Powertrain Control Module Connector Terminals
G09136862Courtesy of FORD MOTOR CO.
Pin Circuit
E20 UO2SPCT11 (Universal Oxygen Sensor Pumping Current Trim Bank 1, Sensor 1)
E8 UO2SPC11 (Universal Oxygen Sensor Pumping Current Bank 1, Sensor 1)
E47 UO2SHTR11 (Universal Oxygen Sensor Heater Bank 1, Sensor 1)
E19 UO2SGREF11 (Universal Oxygen Sensor Ground Reference Bank 1, Sensor 1)
E7 UO2S11 (Universal Oxygen Sensor Bank 1, Sensor 1)