Pinpoint Tests: Notes

A Single Exterior Mirror Is Inoperative 

Refer to Wiring Diagrams Cell 124 for schematic and connector information.

Normal Operation and Fault Conditions 

The RJB fuse 4 (25A) supplies voltage to the DDM and RJB fuse 5 (25A) supplies voltage to the PDM at all times. Each exterior mirror uses a common circuit for both up/down and right/left movement.

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Conditions
B1302:11 Mirror Motor Common: Circuit Short To Ground This DTC is set if the DDM or PDM senses excessive current draw when voltage is applied to the mirror common circuit, when the mirror is commanded UP or LEFT.
B1302:15 Mirror Motor Common: Circuit Short To Battery or Open This DTC is set if the DDM or PDM senses lower than expected current draw when voltage is applied to the mirror common circuit, when the mirror is commanded UP or LEFT.

Possible Causes