Transfer Case Draining And Filling: Draining
- Follow the health and safety precautions. Refer to: Health and Safety Precautions .
- With the vehicle in N, position it on a hoist. Refer to: Jacking and Lifting - Overview .
- If equipped. Remove the retainers and the underbody shield.
- Remove the PTU drain plug.
- Install the PTU drain plug.
Torque: 33 lb.ft (45 Nm)