Solenoid Operation Chart

Base Selector Lever Position  PCM Commanded Gear  SSA NL (CB 1, 2, 3, 4)  SSB NH (3, 5, R)  SSC NL (CB 2, 6)  SSD NH (CB L, R/C 4, 5, 6)  SSE (On/Off) NC  TCC NL 
P P Off On Off Off On Off
R R Off Off Off Off On Off
N N Off On Off Off On Off
D 1 On On Off Off (1) On (2) Off
2 On On On On Off Off
3 On Off Off On Off Off
4 On On Off Off Off On/Off
5 Off Off Off Off Off On/Off
6 Off On On Off Off On/Off
(1) Turns on above 8 km/h (5 mph).
(2) Turns off above 8 km/h (5 mph).

CB = Clutch brake

NC = Normally closed

NH = Normally high