FixVault

DTC P0130 - O2 Sensor Circuit (Bank 1 Sensor 1)

DTC DESCRIPTION P0130 - O2 SENSOR CIRCUIT (BANK 1 SENSOR 1)

Description:  This DTC sets when a concern is detected with one of the circuits used to determine the oxygen content in the exhaust gas.
Possible Causes: 
  • UO2S circuit open
  • UO2S circuit short to voltage
  • UO2S circuit short to ground
  • UO2SGREF circuit open
  • UO2SGREF circuit short to voltage
  • UO2SGREF circuit short to ground
  • UO2SPC circuit short to voltage
  • UO2SPC circuit short to ground
  • UO2SPCT circuit short to voltage
  • UO2SPCT circuit short to ground
  • Incorrect connections
  • Damaged or corroded terminals
  • Damaged universal HO2S
Diagnostic Aids:  Inspect the connectors for signs of damage, water ingress, or corrosion.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST DZ .