Normal Operation and Fault Conditions
During new module installation, configuration files are loaded into the new module being replaced. If a discrepancy is detected between the modules or an incomplete programming procedure is carried out, a DTC sets.
PPT Z ABS MODULE DTC FAULT TRIGGER CONDITIONS
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| C101F:49 | Generic Valve Failure: Internal Electronic Failure | Sets if the ABS module detects one or more internal failures in the HCU or ABS module. |
| P05D3:57 | Driver Mode Select Switch "A" Range/Performance: Invalid/Incompatible Software Component | Sets when the ABS module receives a selectable drive mode request, but the ABS module is not configured or programmed for the selectable drive mode feature. |
| U1A36:56 | Module Code: Invalid/Incompatible Configuration | Sets due to incomplete or improper module programming procedures. |
| U2017:93 | Control Module Software #2: No Operation | Sets due to incomplete or improper module programming procedures. |
| U2100:46 | Initial Configuration Not Complete: Calibration/Parameter Memory Failure | Sets due to incomplete or improper module programming procedures. |
| U2200:00 | Control Module Configuration Memory Corrupt: General Checksum Failure | Sets due to incomplete or improper module programming procedures. |