FixVault

Generator And Regulator: Specifications

General Specifications 

Item Specification
6.2L V8 - Base Heavy Duty 
Rating 157 amps
Generator amps at 80.6deg.F (27deg.C) 93 amps at 606 rpm (min) to 160 amps at 2, 020 rpm (max)
Generator pulley ratio 2.97:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.2L V8 - Optional Extra Heavy Duty 
Rating 200 amps
Generator amps at 80.6deg.F (27deg.C) 130 amps at 606 rpm (min) to 207 amps at 2, 020 rpm (max)
Generator pulley ratio 2.97:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.2L V8 - Snowplow and Camper Package 
Rating 240 amps
Generator amps at 80.6deg.F (27deg.C) 132 amps at 606 rpm (min) to 240 amps at 2, 020 rpm (max)
Generator pulley ratio 2.97:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.7L Power Stroke Diesel - Primary Base Heavy Duty and Vehicles without Ambulance and Fire Engine Package 
Rating 175 amps
Generator amps at 80.6deg.F (27deg.C) 115 amps at 583 rpm (min) to 175 amps at 1, 941 rpm (max)
Generator pulley ratio 3.09:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.7L Power Stroke Diesel - Primary Base Extra Heavy Duty and Vehicles with Ambulance and Fire Engine Package 
Rating 240 amps
Generator amps at 80.6deg.F (27deg.C) 132 amps at 583 rpm (min) to 240 amps at 1, 941 rpm (max)
Generator pulley ratio 3.09:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
6.7L Power Stroke Diesel - Secondary, if Equipped 
Rating 157 amps
Generator amps at 80.6deg.F (27deg.C) 93 amps at 647 rpm (min) to 160 amps at 2, 158 rpm (max)
Generator pulley ratio 2.78:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
7.3L 2V DEVCT V8 - Primary 
Rating 240 amps
Generator amps at 80.6deg.F (27deg.C) 128 amps at 586 rpm (min) to 240 amps at 1, 986 rpm (max)
Generator pulley ratio 3.03:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
7.3L 2V DEVCT V8 - Secondary, if Equipped 
Rating 157 amps
Generator amps at 80.6deg.F (27deg.C) 81 amps at 586 rpm (min) to 161 amps at 1, 986 rpm (max)
Generator pulley ratio 2.81:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator