FixVault

Pinpoint Test A: Battery Condition Test

  1. Normal Operation and Fault Conditions 

    Battery condition is determined by measuring battery terminal voltage after a specific discharge current is applied for a specified time period.

    Possible Sources 

    • Battery
    • Wiring, terminals or connectors

    Visual Inspection and Pre-checks 

    • Inspect wiring, terminals and connectors.
    • Inspect the battery.
    • Inspect the battery mounting.
    • Inspect high current BJB connections.

  2. A1 TEST THE BATTERY CONDITION

    NOTE: Failure to fully charge the battery before retesting may cause false readings.

    • Using the Diagnostic Battery Charger and the battery cables removed from the battery, verify the battery condition.

    Is the battery OK? 

    Yes  RETURN the battery to service.
    No  If the analyzer reads REPLACE BATTERY or REPLACE-BAD CELL, INSTALL a new battery. REFER to: Battery .