FixVault

Module Configuration and Parameter Chart

The chart describes specific module configuration information:

Module Name Module Address Programmable Module Installation (PMI) Available Reprogram/Flash Capable Requires Adaptive Learning or Calibration Available Programmable Parameters
ABS module 760 Yes Yes Yaw rate sensor calibration None
ACM 727 Yes Yes No None
BCM 726 Yes Yes CEI lock configuration
Private sub nodes configuration
None
CCM 764 Yes Yes Radar alignment None
GWM 716 Yes Yes No None
GFM2 /Upfitter Interface Module (UIM) 7D2 No Yes No None
IPC 720 Yes Yes No None
IPMA 706 Yes Yes Camera alignment None
PCM 7E0 Yes Yes Neutral misfire monitor profile learning procedure Vehicle speed limiting
RCM /Yaw rate sensor (vehicles with collision avoidance) 737 Yes Yes No None
RTM 751 Yes Yes No None
SCCM 724 Yes Yes Private sub nodes configuration None
TCU 754 Yes No No None