FixVault

Oxygen Sensor: Installation

Install new oxygen sensor and torque to 30 ft. lbs. (41 N.m). When installing sensor, do not remove anti-seize compound from threads or add any type of sealant. Reconnect electrical connector. Ensure oxygen sensor boot is 5/16" away from wrench fitting of sensor.

NOTE: Never attempt to reinstall a used oxygen sensor. Reinstallation of sensor without special glass bead thread coating can destroy complete exhaust system.