Removal (Pickup)

  1. Disconnect negative battery cables. Disconnect air cleaner bracket from valve cover. Remove crankcase vent bracket and move aside. Disconnect secondary filter lines. Remove secondary filter adapter.
  2. Loosen vacuum pump hold-down clamp. Rotate pump to gain access to intake manifold bolt. Remove intake manifold. Install screens (J-29664) in cylinder heads.
  3. Remove injection line clamps. Remove injection lines at injection nozzles. Remove lines at pump. Tag lines for reassembly reference. Cap open lines.