FixVault

Float Level (Dry Setting): Notes

    NOTE: Follow procedures to properly adjust float level.
    Fig 1: Dry Float Level Adjustment
    G8672
  1. Remove air horn and gasket from float bowl. Hold float retainer down firmly. Lightly push float down against needle. See Fig 1.
  2. Position a "T" scale over toe of float at a point 3/16" from end of float toe. Measure distance from top of float bowl casting to top of float.
  3. If float level setting varies more than 1/16" from specified setting, proceed as follows: