FixVault

Starter Specifications

STARTER NO-LOAD SPECIFICATIONS(1)

Part No. Series Amps. RPM
1998530 5MT 50-75 6000-11,900
1998524 5MT 50-75 6000-11,900
1998532 5MT 50-75 6000-11,900
1998559 10MT 60-90 6500-10,500
1998560 10MT 70-110 6500-10,700
1998561 10MT 70-110 6500-10,700
1998562 10MT 70-110 6500-10,700
1998563 10MT 70-110 6500-10,700
1998565 10MT 70-110 6500-10,700
1998574 10MT 70-110 6500-11,700
1113589 27MT 120-210 9000-13,400
1113590 27MT 120-210 9000-13,400
(1) Starter requires 10-volts for testing GM models.
PINION CLEARANCE

Application In. (mm)
Pinion-to-Housing (1) .010-.140 (.25-3.56)
Pinion-to-Flywheel Clearance .020 (.6)
(1) Measured between pinion stop (retainer) with pinion in engaged position.