FixVault

Exhaust System Backpressure

Before replacing any components, check exhaust system for restrictions. Use a vacuum gauge or a low-pressure (1-5 psi) pressure gauge to check exhaust system.

If using a vacuum gauge, connect gauge to intake manifold vacuum, and start engine. Observe gauge while holding throttle steady at 2000-2500 RPM. If vacuum gauge reading slowly drops after stabilizing, exhaust system may be restricted.

Remove rubber hose at exhaust manifold AIR pipe check valve, and remove check valve. Install pressure gauge to hose and nipple via Propane Enrichment Device (J26911). Nipple should be inserted into exhaust manifold AIR pipe.

Remove oxygen sensor. Install backpressure tester in place of oxygen sensor. After test is completed, coat oxygen sensor threads with anti-seize compound before installation.