FixVault

Power Locks Do Not Unlock (Utility)

Disconnect door lock relay. Connect fused jumper wire between relay connector terminals "A" (White wire) and "B" (Tan wire). Connect a jumper wire between terminal "E" (Gray wire) and ground. If doors unlock, replace relay. If doors do not unlock, repair open circuit in White wire.