FixVault

Charge Indicator Light Always On

  1. Ensure ignition is off. Disconnect generator connector. Turn ignition on. If charge indicator light does not illuminate, go to next step. If charge indicator light illuminates, go to step 3).
  2. Replace generator. See GENERATOR  under REMOVAL & INSTALLATION. Recheck system.