FixVault

Component Testing

Window Motor

  1. Ignition OFF, disconnect the harness connector at the appropriate M74 window motor.
  2. Install a 25 A fused jumper wire between one of the control terminals and 12 V. Momentarily install a jumper wire between the other control terminal and ground. Reverse the jumper wires at least two times, the M74 window motor should perform the UP and DOWN functions.
    • If it does not perform as specified, replace the M74 window motor.