Installation Procedure
- Attach a lifting device (2 and 3) to the drive motor generator control module assembly at the three identified locations.
- Lift the drive motor generator control module assembly into the vehicle.
- Remove the lifting device and install the ball studs (1). Tighten the ball studs to 10 N.m (89 lb in).
- Install the drive motor generator control module assembly retainers (4) and mounting nuts (3). Tighten the mounting nuts to 9 N.m (80 lb in).
- Install the APM ground strap (1) and APM ground strap nut (2). Tighten the nut to 9 N.m (80 lb in).
- Install the sight shield circuit breaker (2) and secure with bolts (1). Tighten the bolts to 5 N.m (44 lb in).
- Connect the APM assembly connectors (1 and 3) and install any removed locking tabs.
- Connect the APM assembly connector (2) using the following procedure:
- Push the lever up.
- Install the connector (2) onto the terminals by pushing on the connector only.
- Rotate the lever after the terminals are engaged.
- Push the green tab to lock the lever.
NOTE:Install the connector (2) without disturbing the position of the lever. DO NOT use the lever to install the connector in place.
- Remove the caps (3, 6) from the drive motor generator power inverter coolant pipes.
- Connect the drive motor generator power inverter module (PIM) cooling inlet and outlet hoses (4, 5).
- Install the shield circuit harness (1) and terminal fastener (2). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install the PIM 3 phase cables (3, 5) into the PIM distribution box with new seals (6).
- Install the PIM 3 phase cable mounting fasteners (2, 4). Tighten the mounting fastener to 9 N.m (80 lb in).
- Install the PIM 3 phase cable terminal fasteners (1). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install the HV dc battery cable (6) with seal (7) into the PIM distribution box.
- Install the HV dc battery cable mounting fasteners (5). Tighten the mounting fastener to 9 N.m (80 lb in).
- Install the high voltage (HV) dc battery cable terminal fasteners (2). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install the HV dc electric air conditioning compressor module (ACCM) cable (4) with seal (7) into the PIM distribution box.
- Install the HV dc electric ACCM cable mounting fasteners (3). Tighten the mounting fasteners to 9 N.m (80 lb in).
- Install the HV dc electric ACCM cable terminal fasteners (1). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install a new seal (3) on the PIM distribution box.
- Clean the sealing surface of the 3 phase cable cover as necessary.
- Position the 3 phase cable cover (2) onto the PIM distribution box ensuring the seal remains in place.
- Tighten the 3 phase cable cover fasteners (1). Tighten the fasteners to 9 N.m (80 lb in).
- Connect the drive motor generator control module assembly connector (1).
- Fill the power electronics cooling system and test for leaks at all serviced connections. Refer to Generator Control Module Cooling System Draining and Filling .
- Install the sight shield. Refer to Drive Motor Generator Control Module Sight Shield Replacement .
- Install the fender cross brace. Refer to Front Fender Rear Upper Brace Replacement .
- Perform the High Voltage Enabling procedure. Refer to High Voltage Enabling .
- Install the air cleaner. Refer to Air Cleaner Assembly Replacement .
- For control module programming and setup procedures, refer to Control Module References .
Refer to Fastener Caution .
Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.
Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.
Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.
DO NOT use excessively abrasive cleaning tools on the sealing surface. Hand sanding with wet 400 grit sandpaper or use of a hand scraper is recommended.