Brake Pressure Sensor Calibration
WARNING: This page is about a different car, the 2023 GMC Acadia. However, it is still accessible from the selected car via links, so may be relevant.
The brake pressure sensor calibration can be completed with a scan tool using the following steps:
- Place the vehicle on a flat level surface.
- Apply the parking brake, or set the transmission in the Park.
- Release the brake pedal.
- Install the scan tool to the data link connector.
- Ignition - On/Vehicle - In Service Mode
- Select Brake Pressure Sensor Calibration in the Brake System Control Module Configuration/Reset Functions list.
- Follow the scan tool directions to complete the calibration learn procedure.
- Clear any DTCs that may be set.