Application Specification
Metric (English)
Battery Hold Down Retainer Nut 5 N.m (44 lb/in)
Battery Negative Cable @ Battery Sensor Nut 9 N.m (80 lb/in)
Battery Negative Cable Extension Cable @ Frame Rail Fastener 9 N.m (80 lb/in)
Battery Negative Cable Extension Cable @ Shift Cable Bracket Fastener 22 N.m (16 lb-ft)
Battery Negative Cable Ground Fastener 22 N.m (16 lb-ft)
Battery Negative Post Clamp Nut 4.5 N.m (40 lb/in)
Battery Positive Cable @ Battery Distribution Engine Compartment Fuse Block Nut 12 N.m (106 lb/in)
Battery Positive Junction Block Cable Nut 12 N.m (106 lb/in)
Battery Positive Post Clamp Nut 4.5 N.m (40 lb/in)
Battery Sensor Module Fastener 9 N.m (80 lb/in)
Battery Tray Mounting Bolt 22 N.m (16 lb-ft)
Battery Tray Mounting Nut 22 N.m (16 lb-ft)
Engine Wiring Harness Junction Block Mounting Bolt 7 N.m (62 lb/in)
Engine Wiring Harness Junction Block Nut 4.7 N.m (42 lb/in)
Generator Mounting Bolt (LTG, LYX) 22 N.m (16 lb-ft)
Generator Mounting Nut (LTG, LYX) 22 N.m (16 lb-ft)
Generator Mounting Stud (LTG, LYX) 9 N.m (80 lb/in)
Starter Bracket Fastener (Large Bolt) 58 N.m (43 lb-ft)
Starter Bracket Fastener (Small Bolt) 22 N.m (16 lb-ft)
Starter Motor Mounting Bolt (LTG) 22 N.m (16 lb-ft)
Starter Motor Mounting Bolt (LYX) 58 N.m (43 lb-ft)
Starter Motor Mounting Nut (LYX) 58 N.m (43 lb-ft)
Starter Solenoid Cable @ Battery Distribution Engine Compartment Fuse Block Nut (LTG, LYX) 12 N.m (106 lb/in)
Starter Solenoid Cable @ Generator Nut (LTG, LYX) 15 N.m (11 lb-ft)
Starter Solenoid Cable @ Starter Nut (LTG, LYX) 12 N.m (106 lb/in)
Stud 22 N.m (16 lb-ft)