FixVault

Updates Failing On K73 Telematics Control Module Via SPS Programming (PIT6113)

Publication date: 2024-01-18
Reference number: PIT6113

UPDATES FAILING ON K73 TELEMATICS CONTROL MODULE VIA SPS PROGRAMMING

UPDATES FAILING ON K73 TELEMATICS CONTROL MODULE VIA SPS PROGRAMMING

TECHNICAL SERVICE BULLETIN

Reference Number(s): PIT6113, Date of Issue:  Jan 18, 2024

SERVICE INFORMATION

Brand: Model: Model Year: VIN: Engine: Transmission:
from to from to
BrightDrop Zevo 600 2023-2024 All All All All
Brightdrop Zevo 400 2024 All All All All
Cadillac LYRIQ 2023-2024 All All All All
Chevrolet Colorado 2023 All All All All
Chevrolet Blazer EV 2024 All All All All
Chevrolet Silverado EV 2024 All All All All
GMC Canyon 2023 All All All All
Involved Region or Country  North America
Additional Options (RPO) UE1
Condition  Technicians may comment that they cannot update the K73 Telematics Control Module via SPS programming.
The update will fail in approximately 12 minutes.
Cause  This is caused by trying to update the K73 Telematics module with the same update that it currently has installed

CORRECTION

Do not replace any components.

If you experience this concern while programming the K73 Telematics Control Module, then the module is up to date and no further action is required.

NOTE:

If you experience this issue while following the latest version of PIT6065, the software is up to date and you can move on to the next module on the list to program.

SERVICE INFORMATION

Version  1
Modified  01/18/2024 - Created on.