Replace and Program Control Module (UDV or UHS)
To program a replacement or an existing Control Module, perform the following procedure:
- Ignition ON/Vehicle in Service Mode.
- Disconnect Wi-Fi dongle from MDI 2. Install EL-52100 (MDI 2) using wired USB Connection from MDI 2 to PC.
- Install an approved battery maintainer or power supply that provides a steady and stable voltage to support the 12 V system during SPS programming events.
- Access the Service Programming System (SPS) and follow the on-screen instructions.
- Ignition/Vehicle OFF.
- On the SPS Supported Controllers screen, select P16 Instrument Cluster - Graphics Programming and follow the on-screen instructions.
- On the SPS Supported Controllers screen, select P16 Instrument Cluster - Programming and follow the on-screen instructions.NOTE:
If the Setup step fails and the Programming step is successful, perform the Serial Data Authentication Configuration procedure and then repeat the Setup step. Refer to: Serial Data Authentication Configuration
- On the SPS Supported Controllers screen, select P16 Instrument Cluster - Setup and follow the on-screen instructions.
- Clear DTCs.
Ensure programming of this module is performed using the EL-52100 (MDI 2). Using the EL-47955 (MDI) will result in a programming failure.
In the event that an SPS selection screen appears and selecting Hardware ID is required, this refers to the new Instrument Panel Cluster Control Module hardware Bootloader part number which can be viewed in GDS2
If Ethernet programming fails, ensure Instrument Cluster is communicating over Ethernet properly. Refer to Scan Tool Does Not Communicate with Vehicle