Reprogram Control Module (UDV or UHS)

To program a replacement or an existing Control Module, perform the following procedure:

  1. Ignition ON/Vehicle in Service Mode.
  2. NOTE:

    Ensure programming of this module is performed using the EL-52100 (MDI 2). Using the EL-47955 (MDI) will result in a programming failure.

  3. Disconnect Wi-Fi dongle from MDI 2. Install EL-52100  (MDI 2) using wired USB Connection from MDI 2 to PC.
  4. Install an approved battery maintainer or power supply that provides a steady and stable voltage to support the 12 V system during SPS programming events.
  5. Access the Service Programming System (SPS) and follow the on-screen instructions.
  6. Ignition/Vehicle OFF.
  7. On the SPS Supported Controllers screen, select P16 Instrument Cluster - Graphics Programming and follow the on-screen instructions.
  8. On the SPS Supported Controllers screen, select P16 Instrument Cluster - Programming and follow the on-screen instructions.
  9. NOTE:

    If Ethernet programming fails, ensure Instrument Cluster is communicating over Ethernet properly. Refer to Scan Tool Does Not Communicate with Vehicle

  10. Clear DTCs.