FixVault

Signal Waveform & Data

Fig 1: Screen Display - Normal Waveform Of APS1 & APS2 With No Acceleration
G11342074Courtesy of HYUNDAI MOTOR AMERICA
Fig 2: Screen Display - Normal Waveform Of APS1 & APS2 With Acceleration
G11342075Courtesy of HYUNDAI MOTOR AMERICA
Fig 3: Screen Display - Normal Data Of APS1 & APS2 At IG ON
G11342076Courtesy of HYUNDAI MOTOR AMERICA
Fig 4: Screen Display - Abnormal Data Of APS1 & APS2 When APS1 & APS2 Circuit Open
G11342077Courtesy of HYUNDAI MOTOR AMERICA

Signal waveform of APS 1 & 2 shows that APS 2 increases voltage just half of APS 1 voltage increase when accelerating.