FixVault

Repair Procedures: Removal

  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Disconnect the purge control solenoid valve connector (A).
  3. Disconnect the vapor hoses (B) from the purge control solenoid valve.
  4. Remove the valve from the bracket.
Fig 1: Purge Control Solenoid Valve Connector And Vapor Hoses
G11412215Courtesy of HYUNDAI MOTOR AMERICA