FixVault

Repair Procedures: Removal

  1. Switch "OFF" the ignition and disconnect the negative (-) battery terminal.
  2. Disconnect the CVVT oil control valve connector (A).
  3. Remove the installation bolt (B), and then remove the valve from the engine.

    CVVT oil control valve mounting bolt: 

    9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)

    [Bank 1/Exhaust] 

    G15586866Courtesy of HYUNDAI MOTOR AMERICA