FixVault

Charging System - 2.5L: Battery: Installation

  1. Install in the reverse order of removal.
    NOTE:
    • When installing the battery, fix the mounting bracket on the tray correctly.

    AGM Battery Charging 

    Information 

    • Check the battery charge state, and then charging the battery if require charging.
    NOTE:
    • The battery temperature should be maintaining at 20°C - 30°C (68°F - 86°F) while the battery charging.

    IU or WU Charging Method 

    IU or WU Charging Voltage: 14.7 V [20°C - 30°C (68°F - 86°F)] approx. 24 hr

    Min Charging Voltage [20°C (68°F)]: 14.4 V

    Max Charging Voltage [20°C (68°F)]: 14.8 V

    Recommend 10% capacity of charging current (ex. 60 Ah: 100% = Charging current 6.0 A)

    WARNING:
    • Do not charge the battery more than 15.2V.
    • Do not rapid charge the battery.
    • Do not open the AGM battery upper case.
    NOTE:
    • If the battery is charged directly at the battery terminals on vehicles with battery sensor, misinterpretations of battery condition and under certain circumstances also unwanted Check Control messages or fault memory entire can occur.
    • After recharging finished, let the battery stand for over 10 hours with normal temperature for battery stabilization.