FixVault

Rectifier Test

  1. With rectifier assembly on bench, contact diode plate with one probe and each of 3 diode leads with other probe. Note ohmmeter reading. Reverse probes, and repeat test for all diodes.
  2. All diodes should show a low reading in one direction and no reading in opposite direction. If any rectifier diode is defective, replace rectifier assembly.