FixVault

Cooling System Specifications

COOLING SYSTEM SPECIFICATIONS

Application Specification
Cooling System Capacity (1) 4.2 Qts. (4.0L)
Pressure Cap 13 psi (90 kPa)
Thermostat Opening
"A" Thermostat 190°F (88°C)
"B" Thermostat (2) 197°F (92°C)
(1) Includes heater core.
(2) "B" thermostat is used in Metro XFi. Ensure replacement thermostat has same temperature specification as original.
NOTE: For thermoswitch, relay and motor testing, see COMPONENT TESTING. For cooling fan system testing, see appropriate SYSTEM TESTING procedure. Refer to ENGINE COOLING FAN article in the ENGINE COOLING section.