FixVault

Test No. 5

  1. Disconnect door lock control module connector. Turn ignition on. Connect fused jumper wire between ground and lock control module connector terminal No. 2 (Green/White wire). If indicator does not light, go to next step. If indicator lights, check for poor connection at lock control module connector. If okay, replace lock control module.
  2. Using fused jumper connected to ground, backprobe instrument panel cluster 16-pin connector terminal No. 10 (Green/White wire). If indicator lights, repair open in Green/White wire between cluster connector and lock control module. If indicator does not light, check for poor connection at cluster connector. If okay, repair or replace IP cluster printed circuit.