FixVault

DTC A017 - Abs Enable Relay Coil Circuit Shorted To Ground: Notes

NOTE: For circuit and connector terminal identification, see WIRING DIAGRAMS .

Ignition voltage is supplied through terminal No. 1 of the ABS enable relay. The EBCM engages pull-in coil of relay by completing the ground circuit at terminal No. 22 of the EBCM. This energizes relay windings, closing the internal contacts which supplies power to the motors and solenoids.

DTC A017 can set before the EBCM commands the ABS enable relay on.

NOTE: Test numbers refer to test numbers on diagnostic chart.
  1. Indicates if EBCM is capable of controlling the ABS enable relay as commanded.
  2. Checks to ensure ABS enable relay or control circuit No. 6V01 is not shorted to ground.
  3. Ensures DTC was not set due to a poor connection.