Primary Resistance Test
Turn ignition off. Remove positive and negative wires from coil. Connect an ohmmeter probe to each primary terminal. Resistance should be 1.78-2.08 ohms at 70°F (21 °C).
Turn ignition off. Remove positive and negative wires from coil. Connect an ohmmeter probe to each primary terminal. Resistance should be 1.78-2.08 ohms at 70°F (21 °C).