HITACHI Electronic Ignition - HONDA: Overhaul: Disassembly
- Remove all spark plug wires and vacuum hoses from the distributor. Remove distributor cap. Remove the condenser ground wire, and disconnect pulse generator/ignitor wire connector from distributor. Remove hold-down bolt, and lift distributor from cylinder head.
- Carefully pry upward on reluctor with 2 screwdrivers, cushioned with rags to prevent damage to distributor housing. See Fig 1. Use care not to damage reluctor or stator.
- Remove advance (or retard) diaphragm mounting screw. Pull out on diaphragm unit, while lifting up on end of diaphragm arm.
Use cloths and screwdrivers to pry off reluctor.
- On all models, drive roll pin from distributor shaft. Remove shaft and gear from housing. Inspect and replace parts as necessary.