THERMOVALVE Test
- Drain engine coolant until level is below distributor holder. Remove the distributor holder and thermovalve. Attach vacuum pump and apply vacuum to thermovalve.NOTE: Install additional vacuum hose on open vacuum port to prevent water from entering valve.
- Suspend thermovalve in cold water. Slowly heat water and note temperature and vacuum readings. Make certain thermometer does not contact bottom of container.
- Thermovalve "A" should open below 60°F (15°C) and not hold vacuum. Valve should close above 77°F (25°C) and hold vacuum. Thermovalve "B" should open below 104°F (40°C) and close above 122°F (50°C).