Vacuum Switch A
- Disconnect vacuum hose No. 4 to control box at vacuum hose manifold. Connect a hand vacuum pump to hose. Check for continuity between White/Blue wire terminal and body ground.
- Apply over 1.2 in. Hg to vacuum switch. Continuity should be present. Release vacuum. There should be no continuity. If switch does not operate as described, replace vacuum switch.