FixVault

Passenger's Window

With the ignition switch in RUN or START, voltage is applied to the coil of the power window relay. The contacts of the power window relay close and voltage is applied through fuse 5 to the passenger's power window switch and the driver's power window switch. If you close the master switch in the driver's power window switch, the passenger's window can be operated from the individual window switch or from the driver's power window switch.

When your move the passenger's power window switch to UP, voltage is applied to the passenger's power window motor. The motor is grounded through the contacts in the passenger's power window switch and the driver's power window switch. The window moves up as long as the switch is held in the UP position. If the passenger's power window switch is moved to DOWN, voltage is applied to the passenger's power window motor in the opposite direction. The window moves down as long as the switch is helped in the DOWN position.

When the driver's passenger window switch is moved to UP, voltage is applied through the passenger's power window switch contacts to the passenger's power window motor. The motor is grounded through the contacts in the passenger's power window switch and the driver's power window switch. The window moves up as long as the switch is held in the UP position. If the driver's passenger window switch is moved to DOWN, voltage is applied to the passenger's power window motor in the opposite direction. The window moves down as long as the switch is held in the DOWN position.