Oil Pump Specifications

WARNING: This page is about a different car, the 1996 Honda Accord and 1995 Honda Accord. However, it is still accessible from the selected car via links, so may be relevant.
OIL PUMP SPECIFICATIONS

Application Specification
Inner Rotor-To-Outer Rotor Radial Clearance
Standard 0.001-0.006" (0.02-0.16 mm)
Service Limit 0.008" (0.20 mm)
Pump Housing-To-Rotor Axial Clearance
Standard 0.001-0.003" (0.02-0.08 mm)
Service Limit 0.005" (0.13 mm)
Pump Housing-To-Outer Rotor Radial Clearance
Standard 0.004-0.007" (0.10-0.19 mm)
Service Limit 0.008" (0.20 mm)
Minimum Oil Pressure At 176°F (80°C)
At Idle 10 psi. (0.7 kg/cm2 )
At 3000 RPM 50 psi. (3.5 kg/cm2 )