Catalytic Converter Monitor Code
NOTE:
- Do not turn the ignition switch OFF.
- When the battery negative cable is disconnected, all readiness codes are cleared.
- When the ECM/PCM is cleared with the OBD II scan tool or Honda PGM Tester, all readiness codes are cleared.
Required condition:
- Ambient temperature between 20-95°F (-7-35°C).
- Connect the scan tool to the Data Link Connector.
- Start the engine. Hold it at 3,000 RPM with no load (in Park or neutral) until the radiator fan comes on.
- Drive for about 10 minutes, without stopping, on a highway. Your speed can vary.
- With the A/T in D4 position or M/T in 5th gear, drive at a steady speed between 50-60 mph (80-100 km/h) for 30 seconds.
- Repeat step 4 three times. Between each repetition, close the throttle completely for 1-2 seconds. If the engine is stopped during this part of the procedure, repeat steps 3, 4, and 5.
- Check for the readiness code with the scan tool.