FixVault

Air Conditioning System

MEASUREMENT SPECIFICATION

Item Measurement Qualification Standard or New
Refrigerant Type   HFC-134a (R-134a)
Capacity of system   500-550 g (17.6-19.4 oz)
Refrigerant oil Type   SANDENSP-10(P/N38897-P13-A01AHor38899-P13-A01)
Capacity of components Condenser 15mL (1/2floz)
Evaporator 35mL (1 1/6floz)
Each line and hose 10mL (1/3floz)
Receiver 10mL (1/3floz)
Compressor 130-150 mL (4 1/3-5floz)
Compressor Field coil resistance At 68 °F (20 °C) 3.05-3.35 a
Pulley-to-armature plate clearance   0.50+/-0.15 mm (0.020+/-0.006 in.)
Compressor belt
NOTE: Adjust a New belt to the new belt spec, run the engine for 5 minutes, then readjust it to the used belt spec.
Deflection with 98 N (10 kgf, 22 lbf) applied mid-way between pulleys Used belt 7.5-10.5 mm (0.30-0.41 in.)
new belt 4.0-6.0 mm (0.16-0.24 in.)
Tension (measured with belt tension gauge) Used belt 390-540 N (40-55 kgf, 88-121 lbf)
New belt 930-1, 125 N (95-115 kgf, 209-254 lbf)