Air Mix Control Motor Test
- Disconnect the 5P connector from the air mix control motor.NOTE: Incorrectly applying power and ground to the air mix control motor will damage it. Follow the instructions carefully.
- Connect battery power to the No. 1 terminal of the air mix control motor, and ground the No. 5 terminal; the air mix control motor should run, and stop at Max Hot. If it doesn't, reverse the connections; the air mix control motor should run, and stop at Max Cool.
- If the air mix control motor did not run in step 2, remove it, then check the air mix control linkage and doors for smooth movement.
- If the linkage and doors move smoothly, replace the air mix control motor.
- If the linkage or doors stick or bind, repair them as needed.
- if the air mix control motor runs smoothly, go to step 4.
- Measure the resistance between the No. 2 and No. 3 terminals. It should be between 4.2 to 7.8 kΩ.
- Measure the resistance between the No. 2 and No. 4 terminals.
Max Cool-0.58 to 1.09 k Ω
Max Hot-3.52 to 6.55 k Ω
- If either of the resistance readings are not as specified, replace the air mix control motor.