FixVault

Change Lever Clearance Inspection

  1. Measure the clearance between change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance is more than the service limit, go to step  2.

    Standard: 0.05-0.25 mm (0.002-0.010 in.) 

    Service Limit: 0.5 mm (0.020 in.) 

    Fig 1: Measuring Clearance Between Change Lever & Select Lever With Feeler Gauge
    G05449436Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Measure the groove width of the select lever.
    • If the groove width is not within the standard, replace the change lever.
    • If the groove width is within the standard, replace the select lever.

    Standard: 15.00-15.10 mm (0.591-0.594 in.) 

    Fig 2: Measuring Groove Width Of Select Lever
    G05449437Courtesy of AMERICAN HONDA MOTOR CO., INC.