Torque Converter Housing
›
Lubrication Check Valve Replacement
Lubrication Check Valve Replacement
Remove the sealing bolt (A) and the sealing washer (B).
Fig 1: Sealing Bolt, Sealing Washer And Lubrication Check Valve With Torque Specification
Remove the lubrication check valve (C) from the torque converter housing.
Install the lubrication check valve, a new sealing washer, and the sealing bolt.