Enable Conditions

ENABLE CONDITIONS

Condition Minimum Maximum
Engine speed - 4,400 rpm(1)
4,800 rpm(2)
Battery voltage 10.5 V -
Commanded EGR valve lift 0.012 in. (0.3 mm) -
No active DTCs P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0134, P0135, P0154, P0155, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0335, P0339, P0401, P0406, P1128, P1129, P1172, P1174, P2195, P2197, P2237, P2238, P2240, P2241, P2243, P2245, P2247, P2249, P2251, P2252, P2254, P2255
(1) J35A6 engine
(2) J35A7 engine