Blower Unit Removal/Installation
- Remove the dashboard (see
DASHBOARD/ STEERING HANGER BEAM REMOVAL/INSTALLATION
).
- Disconnect the recirculation control cable from the recirculation control linkage (see
RECIRCULATION CONTROL CABLE ADJUSTMENT ).
- Disconnect the connector (A) from the blower motor, then remove the mounting bolt, the self-tapping screws, and the bracket (B).
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Remove the clip (A). Remove the mounting bolt, the screws, and the bracket (B). Remove the connector clip (C). Remove the self-tapping screws and the blower unit (D).
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Install the blower unit in the reverse order of removal. Make sure that there is no air leakage.