FixVault

Enable Conditions

ENABLE CONDITIONS

Condition Minimum Maximum
Engine speed - 4,400 rpm
Battery voltage 10.5 V -
Commanded EGR valve lift 0.3 mm (0.012 in.) -
No active DTCs P0107, P0108, P0112, P0113, P0117, P0118, P0134, P0135, P0154, P0155, P0335, P0339, P0401, P0406, P0641, P1128, P1129, P1172, P1174, P2195, P2197, P2237, P2238, P2240, P2241, P2243, P2245, P2247, P2249, P2251, P2252, P2254, P2255, P2413, P2627, P2628, P2630, P2631